PUE-6 (1985), Chapter 7.1 Residential buildings — clause by clause

Clause-by-clause review of PUE-6 ch. 7.1: intakes, risers, flat boards, sockets without earthing, kitchen stoves — and differences from PUE-7.

🇷🇺 PUE — Rules for Electrical Installations (7th ed.)🕰️ PUE-6 — Rules for Electrical Installations (6th ed., 1985)🇺🇸 NEC — National Electrical Code (NFPA 70)🇪🇺 IEC 60364 / HD 60364 (EU national codes)🌎 NOM-001-SEDE, NBR 5410, AEA 90364, RETIE, NCh 4, CNE🇨🇳 GB 50054, GB 50303, JGJ 16, GB/T 16895 (IEC 60364)🇮🇳 IS 732

Document

DocumentPUE-6 (1985), Chapter 7.1 Residential buildings
Edition1985 (ПУЭ-6)
StatusHistorical (replaced by PUE-7 ch. 7.1 in 2003)
Issued byMinistry of Energy of the USSR
Applies toResidential and public buildings, 1985 edition

Document structure

№Chapter / section
7.1.1–7.1.20General building requirements
7.1.21–7.1.45Intakes, boards, meters
7.1.46–7.1.70Wiring, luminaires
7.1.71–7.1.90Sockets, switches, kitchens
PUE-6 (1985), Section 1PUE-6 (1985), Chapter 7

General (7.1.1–7.1.20)

Supply 380/220 V with earthed neutral; separate group circuits for lighting and power.

Intakes and boards (7.1.21–7.1.45)

7.1.24–28 Risers with flat branches via flat boards.

7.1.36 Flat board: intake switch + group fuses/breakers.

Wiring (7.1.46–7.1.70)

7.1.55 Aluminium 2.5 mm² standard (APPV/APV); copper 1.5 mm².

7.1.61 Sockets in bathrooms prohibited.

7.1.62 Switches at 1.5–1.7 m; sockets at 0.8–1.0 m.

Kitchens and stoves (7.1.71–7.1.90)

7.1.75–80 Electric stoves: dedicated circuit, TN-C earthing via PEN.

Differences from PUE-7

Design with GorkyCAD Pro

Automatic single-line diagrams, PUE/GOST/IEC calculations, specification and PDF — from one model.

Start free

Data is for reference. Final design decisions must follow current regulations and a qualified engineer.
← Back to the country: USSR PUE-6: history of Soviet electrical rules · World electrical installation rules