US National Electrical Code (NEC, NFPA 70): 120/240 V 60 Hz, AWG wiring, GFCI and AFCI protection, ampacity tables, differences from PUE and IEC.
| Document | NEC — National Electrical Code (NFPA 70) |
| Voltage | 120/240 V |
| Frequency | 60 Hz |
| Sockets | NEMA 5-15R etc. |
| Earthing | TN-C-S (grounded neutral + equipment ground) |
| Native term | Transliteration | English translation |
|---|---|---|
| ampacity | ampacity | maximum current a conductor can carry |
| branch circuit | branch circuit | final circuit from breaker to outlets |
| feeder | feeder | supply circuit between panel and distribution |
| service entrance | service entrance | point where utility power enters |
| grounding electrode | grounding electrode | earth electrode (rod, plate) |
| bonding jumper | bonding jumper | equipotential bonding conductor |
| GFCI | GFCI | ground-fault circuit interrupter (RCD) |
| AFCI | AFCI | arc-fault circuit interrupter |
| raceway / conduit | raceway / conduit | piping or tray for wires |
| AWG | AWG | American Wire Gauge (wire size) |
| disconnect | disconnect | load-break switch at equipment |
NEC (National Electrical Code), officially NFPA 70, is the US national electrical installation code developed by NFPA. It is updated every 3 years (current edition — 2023). NEC is mandatory in most states and is the basis for many Latin American and Asian codes. Canada has a close code: CE Code (CSA C22.1).
The US household network is 120/240 V, 60 Hz, single-phase three-wire (split-phase): two 120 V hot legs to neutral and 240 V between them. Sockets follow NEMA: 5-15R (15 A, 125 V, grounded), 5-20R (20 A), 14-50R (50 A, for stoves and EV chargers). Wires are sized by AWG (the smaller the number, the thicker the wire).
A key NEC feature is the broad GFCI (Ground-Fault Circuit Interrupter, an RCD equivalent) requirement: bathrooms, kitchens, outdoors, garages, basements, near sinks (art. 210.8), tripping at 4–6 mA. The second unique device is AFCI (Arc-Fault Circuit Interrupter): arc-fault protection mandatory for bedrooms and most dwelling circuits (art. 210.12). Both are built into breakers or receptacles.
Ampacity follows NEC tables (Table 310.16 for copper/aluminium at 60/75/90 °C). Installation rules: NM cables (Romex®) in dry locations, metal conduit (EMT/RMC) and raceways elsewhere; grounding and bonding per art. 250 (grounding electrode, bonding jumper).
| Parameter | NEC (US) | PUE (RF) |
|---|---|---|
| Household voltage | 120/240 V, 60 Hz | 230/400 V, 50 Hz |
| Conductor sizes | AWG (12 AWG ≈ 3.31 mm²) | mm² (1.5, 2.5, 4…) |
| Socket protection | GFCI + AFCI | RCD 30 mA |
| Receptacles | NEMA 5-15R | Type C/F |
| Update cycle | 3 years | Chapter by chapter |
NEC-based rules apply in the USA (NFPA 70), many Latin American states (Mexico NOM-001-SEDE, Colombia NTC 2050, Peru CNE), the Philippines (PEC), several Caribbean and Middle East countries. Canada uses its own CE Code (CSA C22.1), structurally close to NEC.
Translation of key sections and clauses with numbers:
Automatic single-line diagrams, PUE/GOST/IEC calculations, specification and PDF — from one model.
Start freeData is for reference. Final design decisions must follow current regulations and a qualified engineer.